TS120温度冲击试验箱
Temperature range
of the hot chamber

from +50 °C to +220 °C
Temperature range
of the cold chamber
from -80 °C to +70 °C

详细介绍

Test space capacity approx. 120 l
 
Temperature range
of the hot chamber
 
from +50 °C to +220 °C 
Temperature range
of the cold chamber 
from -80 °C to +70 °C
 
Standard features ...

? Powder coated housing made of galvanised steel sheet
? Window, 355 mm x 355 mm, in the hot chamber
? 1 Ultra-lightweight shelf incl. rails
? Cradle in loading position locked
? Max. loading capacity of cradle 50 kg
? 80 mm leadthrough
? volume compensation system for long-term operation
? water-cooled refrigeration unit
? CFC-free refrigeration cycle
? Comfortable 12“ Colour-Touchpanel
? Controlpad for door with status indication
? Highly efficient 32 bit control and monitoring system SIMPAC
? Interfaces USB and ethernet
? Digital-I/O, potential-free 24 V, 4 freely disposable inputs/outputs
? Independent adjustable temperatur limiter tmin/tmax in cradle
for hot and cold zone
? Potential free contact for switching-off of test specimens
? adjustable software temperature limiter min/max
? Status display
? Cycle couter, total no. of cycles / remaining run time
? Operating hour counter
? Temperature control using movable sensor in cradle or
alternatively fixed sensor in hot or cold zone
? Defrosting cycles automatic and programable
? Dwell time start programable
? Already programmed and may be called up at any time:
MIL 883 E, method 1010.7 Intensity of test A,B,C,D,F
? Calibration of 2 temperature values
? 1 Operating instruction 
 

 

Performance data


Temperature range of
hot chamber
 

from +50 °C to +220 °C
 
Temperature range of
cold chamber 
from -80 °C to +70 °C
 
Hot or cold chamber may also be utilized as individual temperature chamber.
 
Temperature deviation in time
in centre of working space

Temperature deviation in space 
±0.3 K to ±1.0 K

±0.5 K to ±2.0 K
 
Heating rate of hot chamber according to IEC 60068-3-5
 
14 K/min 
Cooling rate of cold chamber
according to IEC 60068-3-5
 
6,3 K/min.
 
Heating rate of cold chamber
according to IEC 60068-3-5
 
2 K/min.
 
Temperature changing tests:
MIL 883 E, Method 1010.7,
Severity D with 12 kg of IC's
distributed over 3 shelves;
measurement on test speci-
mens
 

 


Adaption time < 15 min.
 
The following standards are met
DIN 40 046, page 14, test Na,
transfer time < 10 sec.;
IEC-60068-2-14, test Na,
transfer time < 10 sec.;
MIL-STD-810 E, method 503;
MIL-STD-883 E, method 1010.7
variants A,B,C,D,F
JEDEC standard JESD22-A101-A
 
Temperature calibration values are measured at 
- 40 °C cold chamber
+ 125 °C hot chamber 

 

Pre-tempering Temperature change rates can be
increased by choice of raised or
lowered temperatures in warm/cold
chamber. 